{"id":78,"date":"2012-03-27T22:52:34","date_gmt":"2012-03-28T02:52:34","guid":{"rendered":"http:\/\/expertpoolbuilders.com\/blog\/?p=78"},"modified":"2012-03-27T22:52:34","modified_gmt":"2012-03-28T02:52:34","slug":"lighting-a-pool-for-safety","status":"publish","type":"post","link":"https:\/\/expertpoolbuilders.com\/blog\/lighting-a-pool-for-safety\/","title":{"rendered":"Lighting a Pool For Safety"},"content":{"rendered":"<p>A commonly overlooked aspect of safety is proper lighting. Here are some tips.<\/p>\n<p>&nbsp;<\/p>\n<p>When talking about safety-specific products, something that\u2019s often taken for granted in the whole equation is lighting.<\/p>\n<p>But this component allows swimmers to see where they\u2019re headed and how far they can swim or dive before bumping into the walls and floor. In a commercial setting, lighting becomes even more important, as it illuminates signs and helps lifeguards identify when people are in distress.<\/p>\n<p>But in the HMAC sector (hotel, motel, apartment and condo), this part of pool design is often done incorrectly. First, the owners of these facilities often have cost concerns.<\/p>\n<p>\u201cThey\u2019re the worst, because they don\u2019t want to spend any money,\u201d says lighting designer Jim Weathers, president of Engineering Associates in Alvord, Texas. \u201cThey don\u2019t want maintenance items. They don\u2019t want to spend $700 for a pool light; they want to spend $350 on a pool light, and they\u2019ll put on the bare minimum. That\u2019s all a cost game.\u201d<\/p>\n<p>A number of facilities also mistakenly use low lighting to set a mood.<\/p>\n<p>But some counter that mood-setting shouldn\u2019t be the priority. \u201cIt\u2019s safety, not just paint it pretty,\u201d says Kent Williams, president of the Professional Pool Operators of America in Newcastle, Calif. \u201cIt has to do with the survivability of the people who swim in your pool.\u201d<\/p>\n<p>Some facility owners and operators further say they want to minimize lighting to save on energy costs. But with new, energy-efficient options such as LED lighting available, that is no longer an excuse.<\/p>\n<p>\u201cYou can justify improving your lighting if you can drop the cost of doing it,\u201d says Alison Osinski, president of Aquatic Consulting Services in San Diego.<\/p>\n<p>Here, experts offer some tips on properly lighting commercial pools and spas for safety.<\/p>\n<p><strong>Know the codes \u2014 and how they don\u2019t apply. <\/strong><br \/>\nVirtually all codes on the books contain lighting requirements based on watts, prescribing a certain wattage per so many square feet.<\/p>\n<p>But these codes can prove to be outdated. For starters, lighting technology has greatly evolved since the 1970s and \u201980s, when many of these codes were written. Today\u2019s higher-efficiency lights yield significantly more illumination per watt and don\u2019t require as much energy. These older codes don\u2019t consider the actual light output, which affects safety more than anything.<\/p>\n<p>The Illuminating Engineering Society makes recommendations based on the number of foot candles of illumination to be detected in certain spots. For instance, in indoor pools, a reading taken 6 inches above the water\u2019s surface should indicate a light level of at least 100 foot candles. On outdoor pools, that measurement should be at least 60 foot candles. Illumination levels can be measured using a light meter or photometer.<\/p>\n<p>Some state and municipal codes only call for 3 foot candles \u2014 well below that called for by the IES. But some professionals consider that too dark. \u201cIt\u2019s low and just so out of industry standard,\u201d Osinski says.<\/p>\n<p>Many facility designers overlook light levels on the deck, which is important to ensure that signage is readable, Osinski adds. The IES suggests a minimum of 30 foot candles be detected at eye level on the deck.<\/p>\n<p><strong>Do not use lighting directly over the pool. <\/strong><br \/>\nSome aquatic facilities will install lighting directly over the water \u2014 not on poles around the pool perimeter, but rather on rafters, catwalks and other structures reaching across the vessel. This is a bad idea for a number of reasons.<\/p>\n<p>\u201cIt creates a serious glare problem for lifeguards,\u201d Osinski says. \u201cWhat they see is the light reflecting back at them. They see a perfectly round circle [of light] in the pool and absolutely nothing below it.\u201d<\/p>\n<p>And, with the potential for a bulb to shatter and fall in the water, this placement actually causes safety problems.<\/p>\n<p>Finally, this kind of configuration doesn\u2019t promote proper maintenance. \u201cEvery time I see one of those pools with the lights over them, I look up and about five of them are burned out,\u201d Osinski says. \u201cI say, \u2018When do you change them?\u2019 And I hear, \u2018Oh, when half are burned out.\u2019 That\u2019s because it\u2019s really hard to change the bulbs.\u201d<\/p>\n<p>Rather than placing lights directly above the pool, they can be installed on the perimeter and angled toward the water. This way, the glare is reduced and it\u2019s much easier to change the bulbs.<\/p>\n<p><strong>Light the pool uniformly. <\/strong><br \/>\nThe goal not only is to help swimmers read signs and avoid hitting the bottom of the pool, it\u2019s also to help rescuers see when someone needs help. \u201cYou want to be able to see a body underwater, or a person who\u2019s in distress,\u201d Weathers says. \u201cThe biggest problem I see is probably lack of underwater lighting.\u201d<\/p>\n<p>For this reason, installers should not rely solely on local codes to establish the minimum guidelines. Codes may require a certain number of watts every so many square feet, but this doesn\u2019t take into account the beam spread and how much coverage the lights will provide. \u201cWhen you do calculations based on square footage of surface area, sometimes you have dark places between fixtures,\u201d Weathers says. \u201cYou need to space your fixtures correctly.\u201d<\/p>\n<p>On lazy rivers and other curvy, freeform aquatic elements, space the lights closer together than normal to make sure every inch is illuminated. \u201cYou get so much coverage from each fixture,\u201d Weathers says. \u201cEach one\u2019s different, so you have to really look at the beam spread on the fixture and be able to triangulate that so you don\u2019t have dark spots.\u201d<\/p>\n<p>Getting the best possible light may require designers to incorporate new habits. Especially in HMAC pools, many designers simply place one fixture at the deep end and rely on it to illuminate the whole pool. But the light beam will fade progressively the farther it travels, so the shallow end won\u2019t be well lit. \u201cWhat they should be doing is [placing lights] on the sides, all the way to the point where it becomes too shallow to install a fixture,\u201d Weathers says.<\/p>\n<p>For the shallowest water, such as that found in beach entries and sun shelves, designers should make special considerations. Most underwater lights can only be installed in water that\u2019s 18 inches or more deep. In these spaces, add lights nearby, such as on pole-mounted fixtures.<\/p>\n<p>\u201cYou can light them overhead with flood lights and still penetrate the water,\u201d Weathers says. (But once again, these lights should not be placed on rafters or other structures crossing above the pool. Instead, they can be on poles around the pool perimeter.)<\/p>\n<p><strong>Pay attention to key areas. <\/strong><br \/>\nBathers use the shallow end more often than the deep, so make sure that area is well-lit. \u201cWe used to put six times more bulbs in the shallow end than the deep end, because the deep end has much less of the swimming activity,\u201d Williams says.<\/p>\n<p>Though the deep end may have two to three times more water than the remainder of the pool, he adds, the shallow end likely will hold the vast majority of swimmers. \u201cSo the shallow end needs a lot of light,\u201d Williams says. \u201cAny simple state rule saying you need one illuminator per 1,000 square feet isn\u2019t sufficient.\u201d<\/p>\n<p>Additionally, make sure that drains are well-illuminated, so they can be easily seen for detection of missing or broken outlet covers, says Tom Ebro, a water safety specialist with Aquatic Risk Management in Lutz, Fla.<br \/>\n<strong><br \/>\nUse color sparingly, if at all.<\/strong><br \/>\nIf the goal is to detect the human form in distress as quickly as possible, Ebro says, it\u2019s best to have as much contrast as possible. Thus, the ideal scenario is a light-colored pool interior with white light. Colored lights can interfere with quick recognition of a struggling person. In a commercial setting, avoid colored lighting.<\/p>\n<p><strong>Warn customers about maintenance and replacement.<\/strong><br \/>\nEven when pools and spas begin with the right amount of illumination to meet codes and standards, time can erode that away.<\/p>\n<p>\u201cPart of the problem with lighting is you\u2019ll go in and have a compliant situation with the [right amount of] foot candles, and over a period of time, the ballasts or light will get dirty, and you\u2019ll go to less than [the needed] foot candles,\u201d says Bill Rowley, president of Rowley International Inc. in Palos Verdes Estates, Calif. \u201cNow you\u2019re not compliant and you don\u2019t know it. Then you\u2019ll get into a situation with a lawsuit where you\u2019re less than the [needed] foot candles, and even if it doesn\u2019t have anything to do with the lawsuit, it will be cited.\u201d<\/p>\n<p>When completing a pool and \u201chanding over the keys,\u201d so to speak, designers and builders should warn owners and operators about the need to clean bulbs and ballasts, and to replace lights.<\/p>\n<p>Explain to those in charge of maintenance that they should not wait until half the lights are burned out to begin replacing bulbs. This applies to in-pool lighting and other lighting in the area.<\/p>\n<p>Inform pool owners and operators that too many burned-out bulbs can come back to haunt them if an accident occurs.<\/p>\n<p>\u201cIf you don\u2019t have enough light in a pool [so] that you can\u2019t really perceive what the depth is, you haven\u2019t got a chance,\u201d Rowley says. \u201cI\u2019ve been involved in litigation where lights were burned out, which gave a false indication of the pool depth, and someone dove in and hurt themselves.\u201d<\/p>\n<p>Source: Rebecca Robledo &#8211; Pool and Spa News | 9.30.2011<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A commonly overlooked aspect of safety is proper lighting. Here are some tips. &nbsp; When talking about safety-specific products, something that\u2019s often taken for granted in the whole equation is lighting. But this component allows swimmers to see where they\u2019re &hellip; <a href=\"https:\/\/expertpoolbuilders.com\/blog\/lighting-a-pool-for-safety\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-78","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/posts\/78","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/comments?post=78"}],"version-history":[{"count":1,"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/posts\/78\/revisions"}],"predecessor-version":[{"id":79,"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/posts\/78\/revisions\/79"}],"wp:attachment":[{"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/media?parent=78"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/categories?post=78"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/expertpoolbuilders.com\/blog\/wp-json\/wp\/v2\/tags?post=78"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}